Files
obsidian-yanxin/notes/Unraid Drive Replacement Plan.md
2026-03-28 21:47:21 -07:00

8.2 KiB

Unraid Drive Replacement Plan

Goals

  • Reduce array from 8 to 5 HDD drives
  • Replace consumer SMR drives with enterprise CMR
  • Stay under 20% cumulative failure risk before each purchase
  • Minimize cost and hassle

Current Array (as of 2026-03-28)

Slot Model Serial Size Age Est. AFR Health
Parity 1 ST8000DM004 SMR ZCT2K65B 8TB 5.3yr ~4.5% Had 180 GP errors (cleared)
Parity 2 ST8000DM004 SMR ZCT2K5PQ 8TB 5.3yr ~3.5% Had 19 GP errors (cleared)
Disk 1 ST8000DM004 SMR ZCT2K3FF 8TB 5.3yr ~2.75% Same manufacturing batch as parity drives
Disk 2 ST8000DM004 SMR ZCT2K51K 8TB 5.3yr ~2.75% 1 CRC error, otherwise clean
Disk 3 ST8000DM004 SMR ZCT3XAEJ 8TB 4.8yr ~3.5% Had 10 GP errors, 2 CRC, 72K load cycles
Disk 4 WD40EFRX CMR WD-WCC7K2YF4TDJ 4TB 6.6yr ~2.5% Pristine SMART, only 1.7TB used
Disk 5 ST8000DM004 SMR ZR14W632 8TB 2.5yr ~1.75% 56C lifetime max
Disk 6 ST8000DM004 SMR ZR150CVS 8TB 2.5yr ~1.75% Clean
Cache Samsung 970 EVO S5H9NS0N831296A 1TB 1% wear, excellent
  • Combined monthly failure rate: ~1.9%
  • Hits 20% cumulative failure at ~12 months (Mar 2027)
  • Total data stored: ~25TB, growing ~1TB/year
  • All 7 Seagate drives are consumer desktop SMR — not NAS-grade

Shopping List

# Drive Model Purpose Est. Price
1 Seagate Exos X18 16TB ST16000NM000J Parity 1 ~$220
2 Seagate Exos X18 16TB ST16000NM000J Parity 2 ~$220
3 Toshiba MG08 16TB MG08ACA16TE Data (Disk 1) ~$200
Total ~$640

All are enterprise, CMR, 7200rpm, 5-year warranty.

Timeline

Phase 0 — Now (free)

Remove Disk 4 (WD Red 4TB)

Disk 4 only has 1.7TB used. Other drives have 14.5TB of free space. No purchase needed.

  1. Open Unbalance plugin
  2. Source: Disk 4
  3. Destination: Disk 3, Disk 5, Disk 6 (most free space)
  4. Start transfer (~30 min for 1.7TB)
  5. Verify Disk 4 is empty
  6. Stop array (Main → Stop)
  7. Unassign Disk 4 (click on the drive slot → set to "No Device")
  8. Start array → confirm new configuration
  9. Parity sync will run (~12-18 hrs, array is usable during sync)
  10. Power down, physically remove the 4TB drive, power up

Result: 8 → 7 drives. Keep the WD Red as a cold spare — it has pristine SMART.


Phase 1 — April 2027

Buy: 1x Seagate Exos X18 16TB (~$220) Replace: Parity 1 (ZCT2K65B — worst drive, had 180 GP errors) Remove: Disk 3 (ZCT3XAEJ — next worst, had 10 GP errors + 2 CRC + 72K load cycles)

Cumulative failure risk at this point: ~20%

Step 1: Replace Parity 1

  1. Stop array
  2. Power down server
  3. Remove old Parity 1 drive (sdb, serial ZCT2K65B)
  4. Install new Exos X18 16TB in the same slot
  5. Power up → Main page → verify new drive shows in Parity 1 slot
  6. Start array → Parity sync begins (~12-18 hrs)
  7. Array is fully usable during sync — avoid heavy writes
  8. Wait for sync to complete (check Main page for progress)

Step 2: Remove Disk 3

  1. Open Unbalance plugin
  2. Source: Disk 3 (~4.3TB)
  3. Destination: Disk 1, Disk 2, Disk 5, Disk 6
  4. Start transfer (~2-4 hrs)
  5. Verify Disk 3 is empty
  6. Stop array
  7. Unassign Disk 3
  8. Start array → confirm new configuration → parity sync (~12-18 hrs)
  9. Power down, physically remove old Disk 3, power up

Disposal

  • Old Parity 1 (ZCT2K65B): Recycle — worst error history
  • Old Disk 3 (ZCT3XAEJ): Recycle — 2nd worst

Result: 7 → 6 drives.


Phase 2 — June 2027

Buy: 1x Seagate Exos X18 16TB (~$220) Replace: Parity 2 (ZCT2K5PQ — had 19 GP errors)

Steps

  1. Stop array
  2. Power down, swap Parity 2 with new Exos X18 16TB
  3. Power up → verify drive assignment → Start array
  4. Parity sync (~12-18 hrs)

Disposal

  • Old Parity 2 (ZCT2K5PQ): Recycle

Result: Still 6 drives. Cannot remove another drive yet — remaining 8TB data drives are too full to consolidate without a 16TB data drive.


Phase 3 — October 2027

Buy: 1x Toshiba MG08 16TB (~$200) Replace: Disk 1 (ZCT2K3FF — same batch as old parity, 5.3yr old) Remove: Disk 5 (ZR14W632 — had temperature issues)

Step 1: Replace Disk 1

  1. Stop array
  2. Power down, swap Disk 1 with new Toshiba MG08 16TB
  3. Power up → verify drive assignment → Start array
  4. Rebuild begins (~18-20 hrs) — reconstructs Disk 1's data from parity
  5. Array is usable during rebuild

Step 2: Remove Disk 5

  1. Open Unbalance plugin
  2. Source: Disk 5 (~5.2TB)
  3. Destination: Disk 1 (new 16TB, ~9.4TB free after rebuild)
  4. Start transfer (~3-5 hrs)
  5. Verify Disk 5 is empty
  6. Stop array
  7. Unassign Disk 5
  8. Start array → confirm → parity sync (~12-18 hrs)
  9. Power down, physically remove old Disk 5, power up

Disposal

  • Old Disk 1 (ZCT2K3FF): Recycle — same batch as failed parity drives
  • Old Disk 5 (ZR14W632): Keep as emergency spare — only 2.5yr old, clean SMART

Result: 6 → 5 drives. Migration complete.


Final Array (October 2027)

Slot Drive Size Used Source Brand
Parity 1 Exos X18 16TB New (Apr 2027) Seagate
Parity 2 Exos X18 16TB New (Jun 2027) Seagate
Disk 1 MG08 16TB ~12TB New (Oct 2027) Toshiba
Disk 2 ST8000DM004 8TB ~6.3TB Original Seagate
Disk 6 ST8000DM004 8TB ~5.2TB Original Seagate
  • Usable capacity: 30.6TB (16 + 7.3 + 7.3)
  • Data stored: ~25TB with ~6TB free
  • Growth runway: ~6 years at 1TB/year
  • Annual failure rate: ~4% (down from ~19%)
  • 3 empty drive bays for future expansion

Optional Future Upgrade

When Disk 2 (5.3yr) or Disk 6 (2.5yr) eventually show wear, or if you want more space:

Replace With Cost New usable
Disk 2 → 16TB enterprise Toshiba or WD ~$200-230 38.6TB
Disk 6 → 16TB enterprise Toshiba or WD ~$200-230 48TB

Going all-enterprise (5x 16TB) costs an additional ~$430 and gives 48TB usable (23+ years of growth). No rush — Disk 6 especially is young and healthy.

If a Drive Fails Before Scheduled Replacement

Parity drive fails:

  • Buy the replacement Exos X18 16TB
  • Swap, parity sync, done
  • Other parity still protects the array during sync

Data drive fails (8TB):

  • Array keeps running — data is emulated from parity in real-time
  • Buy a 16TB replacement (must upgrade parity first if no parity is ≥16TB yet)
  • Swap, rebuild, done

Data drive fails (new 16TB):

  • Same process, buy another 16TB
  • Dual parity protects against up to 2 simultaneous failures

Drives to Keep After Migration

Drive Reason
WD Red 4TB (WD-WCC7K2YF4TDJ) Cold spare — pristine SMART despite 6.6yr age
Disk 5 8TB (ZR14W632) Emergency spare — only 2.5yr old

Drives to Recycle

Drive Reason
Parity 1 (ZCT2K65B) 180 GP error history
Parity 2 (ZCT2K5PQ) 19 GP error history
Disk 3 (ZCT3XAEJ) 10 GP errors + 2 CRC + 72K load cycles
Disk 1 (ZCT2K3FF) Same batch as parity drives, 5.3yr

Pending Config Fixes

These can be done anytime from the Unraid WebGUI — no downtime needed:

  • Remove compose.manager plugin (Settings → Plugins → click X)
  • Set disk share security to Private (Settings → Global Share Settings → Disk Shares → No)
  • Set user share security to Private (Shares → each share → SMB Security → Private)
  • Move domains share to cache (Shares → domains → Use Cache → Prefer, Cache Pool → cache)
  • Set up email notifications (Settings → Notification Settings)
  • Configure UPS auto-shutdown (Settings → UPS Settings — CyberPower CP1500 via USB, nut-dw plugin installed)
  • Enable XMP in BIOS at next reboot (RAM: G.Skill DDR3 1600MHz running at 1333MHz)
  • Verify appdata backups — test a restore

SMART Test Schedule (already configured)

  • Weekly short: Sundays 2:00 AM (0 2 * * 0)
  • Monthly extended: 1st of month 3:00 AM (0 3 1 * *)
  • Configured via User Scripts plugin